Skip to product information
Login to see price
White-Rodgers
White-Rodgers WR 50M56U-751 CONTROL FURNACE 120V
Part #114723
To place an order, please call 800-635-1001 or email e-commerce@fisscosupply.com.
Description
White-Rodgers Integrated HIS Furnace Control Kit, 36 in Probe Length, 25 VAC, 0.45 A, 19 s Igniter Warm-Up Time, 30 s Prepurge, Retries: 2 times, 275 s Lockout, Surface Mount,
Item Features
- System diagnostic LED with fault recall
- Fused to protect low voltage system transformers
- Self-test installation routine
- Replaces white-rodgers 50M56-751 and virtually all carrier single stage HSI controls with 120V ignitors
- Controls gas valve, ignitor, blower, inducer, humidifier (both 120V and 24V) and air cleaner
- 50/60 Hz frequency
- 5 to 93% RH (non-condensing) humidity
- 1.5 A at 25 VAC 50/60 Hz 0.6 pf valve relay
- 6 A at 120 VAC 50/60 Hz ignitor relay (resistive)
- 2.2 FLA-3.5 LRA at 120 VAC inducer relay
- 14.5 FLA-25 LRA at 120 VAC circulator relay
- 0.8 sec Flame establishing time
- 2 sec maximum flame failure response time
- 25/60 sec heat delay to-fan-on
- 90/120 sec heat delay to-fan-off
- 2 sec Cool delay to-fan-on
- 5/90 sec cool delay to-fan-off
- 25 sec post purge
- -40 to 176 deg F operating temperature
Product Attribute
| Brand: | White-Rodgers |
|---|---|
| Amperage Rating: | 0.45 A |
| Igniter Warm-Up Time: | 19 s |
| Lockout Time: | 275 s |
| Manufacturer Name: | Emerson Electric |
| Mounting Type: | Surface |
| Prepurge Time: | 30 s |
| Probe Length: | 36 in |
| Retries: | 2 times |
| Voltage Rating: | 25 VAC |