White-Rodgers WR 50A56-956 CONTROL FURNACE 120V
Part #114727
To place an order, please call 800-635-1001 or email e-commerce@fisscosupply.com.
Description
The 50A56-956 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
Application
For York Single Stage HSI Controls
Includes
Controls Gas Valve, Igniter, Blower, Inducer, Humidifier and Air Cleaner
Item Features
- System diagnostics LED with fault recall
- Twinning connection
- Fused to protect low voltage system transformers
- Selectable continuous fan speed
- Third fan speed
- Two stage cooling Y2 input
- -40 to 176 deg F
- 5 to 93 percent relative humidity
- 77 deg F electrical rating
- 1.5 A valve relay
- 6 A ignitor relay
- 2.2 FLA to 3.5 LRA inducer relay
- 14.5 FLA to 25 LRA circulator relay
- 1 uA DC min current
- 0.10 uA DC max current
- 100 M ohm leakage resistance
- Maximum timing specification
- 0.8 sec flame establishing
- 2 sec flame failure response
Standards
CSA Certified|UL Listed
Product Attribute
| Brand: | White-Rodgers |
|---|---|
| Accessory Type: | Replacement Integrated Furnace Control |
| Amperage Rating: | 0.45 A |
| Country of Origin: | MX |
| Depth: | 1-1/4 in |
| Domestic/Import: | Import |
| Gas Type: | Natural, Manufactured, Mixed, LP Gas |
| Height: | 7 in |
| Igniter Warm-Up Time: | 17 s |
| Manufacturer Name: | Emerson Electric |
| Mounting Type: | Surface |
| Voltage Rating: | 25 VAC |
| Width: | 4.825 in |