- Ideal for control gas valve, ignitor, blower motor, inducer, humidifier and air cleaner.
- Microprocessor-based precision.
- Controls inducer and blower fan motors, hot surface igniter, and gas valve.
- Monitors timing, trial for ignition, flame sensing, pressure switches, and limit switches.
- Designed for 100% gas shutoff in case of ignition failure, Reverse polarity protection.
- Compatible with 24 VAC standard thermostat and with LP or natural gas.
- Provides diagnostic LED to aid in testing/troubleshooting.
- Brand: ICMCool Off: 45 seconds secondsCool On: 5 seconds secondsCountry of Origin: USFan (Heat) On/Off Delay: 1 second secondHeat Blower Off: Selectable 90/120/150/180 seconds secondsHeat Blower On: 30 seconds secondsIgniter Warm Up Time: 18 seconds secondsManufacturer Name: ICM ControlsPost-Purge Time: 15 seconds secondsPRE-PURGE TIME: 15 seconds secondsTotal Trials for Ignition: 3 (auto rest after 1 hour)